The JWST Ultramassive Galaxy Sample -- II. Supermassive Black Hole Masses for 8 Extreme Early-Type Galaxies via Jeans Anisotropic Modelling of High-Resolution Integral-Field NIRSpec Stellar Kinematics

ArXiv 2609.2198 (2026)

Authors:

Michele Cappellari, Dieu D Nguyen, Susan A Kassin

TDCOSMO XXIX: JWST/NIRSpec IFU Spatially Resolved Kinematics of Three Time-delay Lenses

(2026)

Authors:

Shawn Knabel, Pritom Mozumdar, Anowar J Shajib, Tommaso Treu, Devon M Williams, Michele Cappellari, David Law, Simon Birrer, Takahiro Morishita, William Sheu, Massimo Stiavelli

TDCOSMO XXVIII. The Hubble constant from the quadruply lensed quasar J1537$-$3010 with precise time delays

(2026)

Authors:

A Galan, AG Schweinfurth, SH Suyu, DP Johnson, A Chawla, D Sluse, GV Kharchilava, E Buckley-Geer, H Lin, S Knabel, W Sheu, S Ertl, T Anguita, S Birrer, F Courbin, F Dux, M Millon, V Motta, S Schuldt, T Treu, DM Williams, M Cappellari, KC Wong, D Eckert

TDCOSMO. XXVII. JWST-based Lens Models and H$_0$ Measurement of WFI2033, HE0435, and PG1115

(2026)

Authors:

DM Williams, T Treu, DP Johnson, P Mozumdar, S Knabel, S Birrer, CD Fassnacht, A Galan, AJ Shajib, KC Wong, M Cappellari, F Courbin, T Morishita, V Motta, D Sluse, M Stiavelli

Comparing the contrast performance of two IFU technologies for exoplanet direct imaging with ELT-PCS

Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation VII SPIE 14154 (2026)

Authors:

Ryan Griffiths, Siddharth Maharana, Matthias Tecza

Abstract:

A key science goal for the Planetary Camera and Spectrograph (ELT-PCS) instrument is to image rocky exoplanets in reflected light around nearby M- and K-dwarfs. These observations will require a contrast of 10−9 at 100 mas angular separation, and 10−8 at 10 mas. To achieve such an extreme performance, every instrument design choice must be carefully evaluated. For ELT-PCS’s science instruments, perhaps the most critical design choice is which integral field unit (IFU) technology to use. To this end, we have developed a modular, lab-based integral field spectrograph test bench with which to compare the performance of two popular IFU technologies: image slicers and lenslet arrays. The test bench implements a Lyot coronagraph and a spatial light modulator to simulate a high-contrast imaging system, which feeds each IFU with a diffraction-limited PSF image. Each IFU is coupled to the spectrograph, which achieves R≈3000 with the image slicer and R≈100 with the lenslet array. The calibration and data reduction for each IFU design are described and the initial results of a contrast comparison are presented. The lenslet array achieves a deeper contrast at angular separations of less than 6λ/D. The image slicer, however, gains more at small separations from applying spectral deconvolution, with a 3.4× greater gain at 4λ/D. Spectral deconvolution further yields a contrast curve close to the detector noise floor. Further work will focus on carrying out a fully-controlled characterisation of the lenslet array IFU and a more comprehensive study into the effects of adaptive optics residuals on the contrast.