ALFA & 3D: integral field spectroscopy with adaptive optics
P SOC PHOTO-OPT INS 4007 (2000) 952-961
Abstract:
One of the most important techniques for astrophysics with adaptive optics is the ability to do spectroscopy at diffraction limited scales. The extreme difficulty of positioning a faint target accurately on a very narrow slit can be avoided by using an integral field unit, which provides the added benefit of full spatial coverage. During 1998, working with ALFA and the 3D integral field spectrometer, we demonstrated the validity of this technique by extracting and distinguishing spectra from binary stars separated by only 0.26 ". The combination of ALFA&3D is also ideally suited to imaging distant galaxies or the nuclei of nearby ones, as its field of view can be changed between 1.2 " x1.2 " and 4 " x4 ", depending on the pixel scale chosen. Ln this contribution we present new results both on galactic targets, namely young stellar objects, as well as extra-galactic objects including a Seyfert and a starburst nucleus.Imaging the universe in 3D with the VLT: the next generation field spectrometer SPIFFI
P SOC PHOTO-OPT INS 4008 (2000) 289-297
Abstract:
We present SPIFFI, the integral field spectrometer for the VLT. This instrument allows simultaneous observation of infrared spectra in more than 1000 image points of a two dimensional field. With its set of four gratings and a pixel scale that can be varied by a factor of ten, SPIFFI provides high flexibility, and at the same time offers the unique possibility of diffraction limited imaging spectroscopy at an 8m-class telescope, when fed by the adaptive optics system MACAO. We outline the scientific drivers for building such an instrument, the concept of image slicing, the optical design, and the implementation of SPIFFI.LUCIFER-MOS: A cryogenic multi object infrared spectrograph for the let
P SOC PHOTO-OPT INS 4008 (2000) 1094-1102
Abstract:
LUCIFER-MOS is a liquid nitrogen cooled near infrared multi object spectrograph imaging 20 freely selectable sub-fields of about 2.2" x 1.8" and 6 x 4 image elements each on the entrance slit of the LUCIFER spectrograph. The image elements are re-arranged by 480 fused silica fibers of 50 mu m core diameter and 100 mu m total diameter with integrated, hexagonal lenslets of 0.6 mm width corresponding to a 0.3" field. The pre-optics magnifies the telescope image by a factor 3.3, thus adapting the telescope plate scale to the lenslet scale, and additionally providing a cold stop. The post-optics converts the f/3 fiber output beam to the f/15 beam accepted by the spectrograph. Each of the 20 6 x 4 fiber arrays together with its pre-optics is mounted in a spider arm which can be freely positioned within the 200 mm diameter field of view by a cryogenic robot. The robot performs three rotational movements to position the spider arms and is driven by cold stepper motors. The spider arms are locked in their positions by two permanent magnets each. Their magnetic field can be compensated by coils to unlock the arms and move them across the field of view.LWS measurements of HD in the giant planets
ISO BEYOND THE PEAKS 456 (2000) 29-32
Near-IR integral field spectroscopy with adaptive optics
ASTR SOC P 195 (2000) 206-215