The EnVision Venus orbiter mission, proposed to ESA

Colin Wilson

Visitor

Research theme

  • Exoplanets and planetary physics

Sub department

  • Atmospheric, Oceanic and Planetary Physics

Research groups

  • Planetary atmosphere observation analysis
  • Planetary surfaces
  • Solar system
  • Space instrumentation
Colin.Wilson@physics.ox.ac.uk
Telephone: 07939202151
Atmospheric Physics Clarendon Laboratory, room 209a
  • About
  • Publications

Spatial variability of carbon monoxide in venus' mesosphere from venus express/visible and infrared thermal imaging spectrometer measurements

Journal of Geophysical Research Planets 114:5 (2009) E00-B01

Authors:

PGJ Irwin, R De Kok, A Negrão, CCC Tsang, CF Wilson, P Drossart, G Piccioni, D Grassi, FW Taylor

Abstract:

[1] Observations of Venus' mesosphere by the Visible and Infrared Thermal Imaging Spectrometer (VIRTIS)-M instrument of Venus Express have been used to investigate the spatial distribution of CO above Venus' nightside cloud tops by fitting the CO absorption in the (1-0) CO band around 4.7 μm. We find little spatial variation in the abundance of CO at midlatitudes, with a retrieved abundance of approximately 40 ± 10 ppm just above the cloud tops between 65 and 70 km altitude. Unfortunately, we find it very difficult to constrain the abundance of CO in the cold polar collar, centered at about 70°S, as the retrieved temperature structure in the CO line-forming region masks the absorption lines. However, there is a possibility that CO increases toward the poles, as we detect a significant signature of high levels of CO over Venus' south polar dipole feature in all the observations analyzed so far. To constrain the abundance of CO more closely will require the analysis of higher-resolution VIRTIS-H observations. In addition, limb observations would greatly help to resolve any possible temperature/cloud ambiguities and allow us to assess vertical variations in the abundance of CO. Copyright 2008 by the American Geophysical Union.

Tropospheric carbon monoxide concentrations and variability on Venus from Venus Express/VIRTIS-M observations

Journal of Geophysical Research Planets 114:5 (2009) E00-B08

Authors:

CCC Tsang, PGJ Irwin, CF Wilson, FW Taylor, C Lee, R De Kok, P Drossart, G Piccioni, B Bezard, S Calcutt

Abstract:

[1] We present nightside observations of tropospheric carbon monoxide in the southern hemisphere near the 35 km height level, the first from Venus Express/Visible and Infrared Thermal Imaging Spectrometer (VIRTIS)-M-IR. VIRTIS-M data from 2.18 to 2.50 μm, with a spectral resolution of 10 nm, were used in the analysis. Spectra were binned, with widths ranging from 5 to 30 spatial pixels, to increase the signal-to-noise ratio, while at the same time reducing the total number of retrievals required for complete spatial coverage. We calculate the mean abundance for carbon monoxide at the equator to be 23 ± 2 ppm. The CO concentration increases toward the poles, peaking at a latitude of approximately 60°S, with a mean value of 32 ± 2 ppm. This 40% equator-to-pole increase is consistent with the values found by Collard et al. (1993) from Galileo/NIMS observations. Observations suggest an overturning in this CO gradient past 60°S, declining to abundances seen in the midlatitudes. Zonal variability in this peak value has also been measured, varying on the order of 10% (∼3 ppm) at different longitudes on a latitude circle. The zonal variability of the CO abundance has possible implications for the lifetime of CO and its dynamics in the troposphere. This work has definitively established a distribution of tropospheric CO, which is consistent with a Hadley cell circulation, and placed limits on the latitudinal extent of the cell. Copyright 2008 by the American Geophysical Union.

Weather and climate on the planets

Weather 63:10 (2008) 313-314

Why we need to go to Venus: The future of European Venus exploration

International Astronautical Federation 59th International Astronautical Congress 2008 Iac 2008 3 (2008) 1622-1629

Authors:

C Wilson, E Chassefière, T Imamura, O Korablev, K Baines, D Titov, K Aplin, TS Balint, J Blamont, C Ferencz, C Cochrane, F Ferri, M Gerasimov, J Leitner, J Lopez-Moreno, B Marty, M Martynov, S Pogrebenko, A Rodin, J Whiteway, L Zasova

Abstract:

Venus is the most Earthlike planet we know besides our own, in terms of its size and distance from its parent star. It was probably formed from the same materials as the Earth and Mars, at a similar time - why then has it become so different?To address this key question, a team of 170+ scientists from around the world formulated the European Venus Explorer (EVE) mission proposal to the European Space Agency's Cosmic Vision Programme in 2007. Although it was not chosen in the 2007 selection round for programmatic reasons, it was rated a high priority for the future European Space Science so we take this opportunity to reiterate the science goals which motivated the EVE mission, and to discuss the status of technological and programmatic developments required to address these goals.

A wind tunnel for the calibration of Mars wind sensors

Planetary and Space Science 56:11 (2008) 1532-1541

Authors:

CF Wilson, AL Camilletti, SB Calcutt, PM Ligrani

Abstract:

A major limitation in the development of wind sensors for use on Mars is the lack of suitable testing and calibration facilities. A low-density wind tunnel has been developed at Oxford University for calibration of wind sensors for Mars landers, capable of providing stable or dynamically varying winds, of air or carbon dioxide, at Martian pressures (5-10 mbar) and speeds (0.5-30 m/s), and temperatures of 200-300 K. The flow field in the test section was calculated using analytical and computational modelling techniques, and validated experimentally using a pitot probe. This facility's stability and accuracy offer significant advantages with respect to previous calibration facilities. © 2008 Elsevier Ltd. All rights reserved.

Pagination

  • First page First
  • Previous page Prev
  • …
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Current page 21
  • Page 22
  • Page 23
  • Page 24
  • Next page Next
  • Last page Last

Footer Menu

  • Contact us
  • Giving to the Dept of Physics
  • Work with us
  • Media

User account menu

  • Log in

Follow us

FIND US

Clarendon Laboratory,

Parks Road,

Oxford,

OX1 3PU

CONTACT US

Tel: +44(0)1865272200

Department Of Physics text logo

© University of Oxford - Department of Physics

Cookies | Privacy policy | Accessibility statement

  • Home
  • Research
  • 51ÁÔÆæÈë¿Ú
  • Engage
  • Our people
  • News & Comment
  • Events
  • Our facilities & services
  • 51ÁÔÆæÈë¿Ú
  • Giving to Physics