51猎奇入口

Skip to main content
Department Of Physics text logo
  • Research
    • Our research
    • Our research groups
    • Our research in action
    • Research funding support
    • Summer internships for undergraduates
  • 51猎奇入口
    • Undergraduates
    • Postgraduates
  • Engage
    • For young people
    • For teachers
    • For the public
    • For alumni
    • For business
  • Support
Menu
Black Hole

Lensing of space time around a black hole. At Oxford we study black holes observationally and theoretically on all size and time scales - it is some of our core work.

Credit: ALAIN RIAZUELO, IAP/UPMC/CNRS. CLICK HERE TO VIEW MORE IMAGES.

Prof. Niranjan Thatte

Professor of Astrophysics

Research theme

  • Astronomy and astrophysics
  • Instrumentation
  • Exoplanets and planetary physics

Sub department

  • Astrophysics

Research groups

  • Astronomical instrumentation
  • Exoplanets and Stellar Physics
  • Galaxy formation and evolution
  • Extremely Large Telescope
Niranjan.Thatte@physics.ox.ac.uk
Telephone: 01865 (2)73412
Denys Wilkinson Building, room 709
  • About
  • Teaching
  • Publications

Teaching Insights

Education

School is to make students 'Yearn to Learn'. College is to get students to 'Learn How to Learn'

Design of the HARMONI pyramid WFS module

AO4ELT 2019 - Proceedings 6th Adaptive Optics for Extremely Large Telescopes (2019)

Authors:

N Schwartz, JF Sauvage, E Renault, C Correia, B Neichel, T Fusco, K Dohlen, K El Hadi, C Petit, E Choquet, V Chambouleyron, J Paufique, F Clarke, N Thatte, I Bryson

Abstract:

漏 2019 AO4ELT 2019 - Proceedings 6th Adaptive Optics for Extremely Large Telescopes. All rights reserved. Current designs for all three extremely large telescopes show the overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or extended objects. The key advantages of the P-WFS over the Shack-Hartmann are known and are mainly provided by the improved sensitivity (fainter NGS) and reduced sensitivity to spatial aliasing. However, robustness and tolerances of the P-WFS for the ELTs are not currently well understood. In this paper, we present simulation results for the single-conjugate AO mode of HARMONI, a visible and near-infrared integral field spectrograph for the European Extremely Large Telescope. We first explore the wavefront sensing issues related to the telescope itself; namely the island effect (i.e. differential piston) and M1 segments phasing errors. We present mitigation strategies to the island effect and their performance. We then focus on some performance optimisation aspects of the AO design to explore the impact of the RTC latency and the optical gain issues, which will in particular affect the high-contrast mode of HARMONI. Finally, we investigate the influence of the quality of glass pyramid prism itself, and of optical aberrations on the final AO performance. By relaxing the tolerances on the fabrication of the prism, we are able to reduce hardware costs and simplify integration. We show the importance of calibration (i.e. updating the control matrix) to capture any displacement of the telescope pupil and rotation of the support structure for M4. We also show the importance of the number of pixels used for wavefront sensing to relax tolerances of the pyramid prism. Finally, we present a detailed optical design of the pyramid prism, central element of the P-WFS.

Near infrared throughput and stray light measurements of diffraction gratings for ELT-HARMONI

Proceedings of SPIE Society of Photo-optical Instrumentation Engineers 10706 (2018)

Authors:

M Rodrigues, John Capone, F Clarke, A Earle, T Foster, J Lynn, K Obrien, M Tecza, NA Thatte, I Tosh, A Hidalgo Valadez, IJ Lewis

Opto-mechanical designs for the HARMONI adaptive optics systems

Proceedings of SPIE SPIE 10703 (2018)

Authors:

K Dohlen, TJ Morris, J Piqueras Lopez, A Calcines-Rosario, A Costille, M Dubbeldam, K El Hadi, T Fusco, M Llored, B Neichel, S Pascal, J-F Sauvage, P Vola, Fraser Clarke, H Schnetler, I Bryson, Niranjan Thatte

Abstract:

HARMONI is a visible and near-infrared integral field spectrograph equipped with two complementary adaptive optics systems, fully integrated within the instrument. A Single Conjugate AO (SCAO) system offers high performance for a limited sky coverage and a Laser Tomographic AO (LTAO) system provides AO correction with a very high sky-coverage. While the deformable mirror performing real-time correction of the atmospheric disturbances is located within the telescope itself, the instrument contains a suite of state-of-the-art and innovative wavefront sensor systems. Laser guide star sensors (LGSS) are located at the entrance of the instrument and fed by a dichroic beam splitter, while the various natural guide star sensors for LTAO and SCAO are located close to the science focal plane. We present opto-mechanical architecture and design at PDR level for these wavefront sensor systems.

System analysis and expected performance of a high-contrast module for HARMONI

SPIE, the international society for optics and photonics 10702 (2018) 107029n

Authors:

Alexis Carlotti, Fran莽ois H茅nault, Kjetil Dohlen, Jean-Fran莽ois Sauvage, Patrick Rabou, Yves Magnard, Arthur Vigan, David Mouillet, Gael Chauvin, Pascal Vola, Mickael Bonnefoy, Thierry Fusco, Kacem El Hadi, Niranjan Thatte, Fraser Clarke, Matthias Tecza, Ian Bryson, Hermine Schnetler, Christophe V茅rinaud

ELT HARMONI: Image Slicer Preliminary Design

GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VII 10702 (2018) UNSP 1070296

Authors:

Florence Laurent, Didier Boudon, Johan Kosmalski, Magali Loupias, Guillaume Raffault, Alban Remillieux, Niranjan Thatte, Ian Bryson, Hermine Schnetler, Fraser Clarke, Matthias Tecza

Pagination

  • First page First
  • Previous page Prev
  • …
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Current page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • …
  • Next page Next
  • Last page Last

Footer Menu

  • Contact us
  • Giving to the Dept of Physics
  • Work with us
  • Media

User account menu

  • Log in

Follow us

FIND US

Clarendon Laboratory,

Parks Road,

Oxford,

OX1 3PU

CONTACT US

Tel: +44(0)1865272200

Department Of Physics text logo

漏 University of Oxford - Department of Physics

Cookies | Privacy policy | Accessibility statement

  • Home
  • Research
  • 51猎奇入口
  • Engage
  • Our people
  • News & Comment
  • Events
  • Our facilities & services
  • 51猎奇入口
  • Giving to Physics