Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
(2011)
Effect of recrystallisation on the radioactive contamination of CaWO 4 crystal scintillators
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 631:1 (2011) 44-53
Abstract:
Minimising intrinsic radioactivity of crystal scintillators is of particular importance for experiments searching for rare events. We studied the impact of the crystal production process (recrystallisation) on the level of radioactive contamination of CaWOStudies of concentration dependences in the luminescence of Ti-doped Al2 O3
Journal of Applied Physics 109:5 (2011)
Abstract:
The variation of luminescence and excitation spectra of titanium doped Al2O3 for the concentration of Ti ranging from 10 to 1000 ppm was investigated using synchrotron radiation. In the lightly doped Al 2O3-Ti (<100 ppm) samples we identified several emission bands. These are the emission of the excitons localized at Ti (290 nm), the emission due to F centers (325 nm), the band around 420 nm traditionally attributed to F center emission, and the luminescence of Ti3+ ions at 720 nm. The emphasis in this study is on the clarification of the nature of the blue emission band in the samples with high concentration of Ti (≥100 ppm), where the luminescence and excitation spectra of the blue emission exhibit noticeable variability. This is explained by a model of the luminescence process of Ti4+-F centers that includes the photoionization of Ti 3+, the subsequent capture of electrons at F-centers, formation of excited F-centers and, finally, the emission of a blue photon. The quenching of the blue emission with increasing Ti concentration is interpreted in terms of competition between oxygen vacancies and Ti4+ centers in the capture of the electron. © 2011 American Institute of Physics.Combined limits on WIMPs from the CDMS and EDELWEISS experiments
Physical Review D - Particles, Fields, Gravitation and Cosmology 84:1 (2011)
Abstract:
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614kg•days equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent weakly interacting, massive particle (WIMP)-nucleon cross section. For a WIMP mass of 90GeV/c2, where this analysis is most sensitive, a cross section of 3.3×10-44cm2 is excluded at 90% C.L. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700GeV/c2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others. © 2011 American Physical Society.Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics 702:5 (2011) 329-335