51ÁÔÆæÈë¿Ú

Skip to main content
Department Of Physics text logo
  • Research
    • Our research
    • Our research groups
    • Our research in action
    • Research funding support
    • Summer internships for undergraduates
  • 51ÁÔÆæÈë¿Ú
    • Undergraduates
    • Postgraduates
  • Engage
    • For young people
    • For teachers
    • For the public
    • For alumni
    • For business
  • Support
Menu
Insertion of STC into TRT at the Department of Physics, Oxford
Credit: CERN

Professor Todd Huffman

Associate Professor of Physics

Research theme

  • Fundamental particles and interactions

Sub department

  • Particle Physics

Research groups

  • ATLAS
  • ePIC
Todd.Huffman@physics.ox.ac.uk
  • About
  • Publications

The radiation induced attenuation of optical fibres below −20°C exposed to lifetime HL-LHC doses at a dose rate of 700 Gy(Si)/hr

Journal of Instrumentation 7 (2012) 01

Authors:

D Hall, B Todd Huffman, A Weidberg

Abstract:

The LHC luminosity upgrade, known as the HL-LHC, will require high-speed optical links to read out data from the detectors. Such links must be capable of withstanding high doses whilst being kept at low temperatures. Two single-mode and two multi-mode fibres were exposed to 200 kGy(Si) at a dose rate of about 700 Gy(Si)/hr, whilst being kept at about -25°C. The radiation induced attenuation of these fibres was measured as the fibres accumulated dose. A conservative estimate has been made of the total attenuation expected for a realistic fibre route through the ATLAS detector after a lifetime dose at the HL-LHC. With safety factors, the maximum dose extrapolated to was 375 kGy(Si). All four fibres performed extremely well and were qualified for use at HL-LHC detectors.

The radiation tolerance of specific optical fibers for the LHC upgrades

PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011) 37 (2012) 1632-1643

Authors:

Joshua Abramovitch, B Arviddson, K Dunn, Datao Gong, Todd Huffman, C Issever, M Jones, Cotty Kerridge, James Kierstead, G Kuyt, Chonghan Liu, Tiankuan Liu, A Povey, E Regnier, NC Ryder, Nnadozie Tassie, Tony Weidberg, Annie C Xiang, Jingbo Ye

The radiation hardness and temperature stability of Planar Light-wave Circuit splitters for the High Luminosity LHC

JINST IOPscience 6 (2011) P10007

Authors:

N Ryder, P Hamilton, BT Huffman, PK Teng, AR Weidberg, C Issever

Abstract:

High Luminosity LHC (HL-LHC) Inner Tracker designs may include the sharing of Timing, Trigger and Control (TTC) signals between several tracker modules. This is possible because the highest frequency signals are common to all modules. Such designs are an attractive option because they reduce the number of optical links required and hence the cost. These designs will require optical signal splitters that are radiation hard up to high doses and capable of operating in cold temperatures. Optical splitters are available as either fused-fibre splitters or Planar Light-wave Circuit (PLC) splitters. PLC splitters are preferable because they are smaller than fused-fibre splitters. A selection of PLC splitters from different manufacturers and of two different technologies (silica and glass based) have been tested for radiation hardness up to a dose of 500 kGy(Si) and for temperature stability. All the tested splitters displayed small increases in insertion losses ( < 0.1 dB) in reducing the operating temperature from 25°C to −25°C. The silica based splitters from all manufacturers did not exhibit significant radiation induced insertion losses, despite the high dose they were exposed to. The glass based sample, however, had a per channel radiation induced insertion loss of up to 1.16 dB. Whilst the silica based splitters can be considered as qualified for HL-LHC use with regards to radiation hardness, the glass technology would require further testing at a lower, more realistic, dose to also be considered as a potential component for HL-LHC upgrade designs.

The radiation hardness and temperature stability of Planar Light-wave Circuit splitters for the High Luminosity LHC

Journal of Instrumentation 6:10 (2011)

Authors:

NC Ryder, P Hamilton, BT Huffman, PK Teng, AR Weidberg, C Issever

Abstract:

High Luminosity LHC (HL-LHC) Inner Tracker designs may include the sharing of Timing, Trigger and Control (TTC) signals between several tracker modules. This is possible because the highest frequency signals are common to all modules. Such designs are an attractive option because they reduce the number of optical links required and hence the cost. These designs will require optical signal splitters that are radiation hard up to high doses and capable of operating in cold temperatures. Optical splitters are available as either fused-fibre splitters or Planar Lightwave Circuit (PLC) splitters. PLC splitters are preferable because they are smaller than fusedfibre splitters. A selection of PLC splitters from different manufacturers and of two different technologies (silica and glass based) have been tested for radiation hardness up to a dose of 500 kGy(Si) and for temperature stability. All the tested splitters displayed small increases in insertion losses (< 0.1 dB) in reducing the operating temperature from 25°C to ?25°C. The silica based splitters from all manufacturers did not exhibit significant radiation induced insertion losses, despite the high dose they were exposed to. The glass based sample, however, had a per channel radiation induced insertion loss of up to 1.16 dB. Whilst the silica based splitters can be considered as qualified for HL-LHC use with regards to radiation hardness, the glass technology would require further testing at a lower, more realistic, dose to also be considered as a potential component for HL-LHC upgrade designs. © 2011 IOP Publishing Ltd and SISSA.

Measurement of the B- lifetime using a simulation free approach for trigger bias correction

Physical Review D Particles Fields Gravitation and Cosmology 83:3 (2011)

Authors:

T Aaltonen, J Adelman, B �lvarez González, S Amerio, D Amidei, A Anastassov, A Annovi, J Antos, G Apollinari, J Appel, A Apresyan, T Arisawa, A Artikov, J Asaadi, W Ashmanskas, A Attal, A Aurisano, F Azfar, W Badgett, A Barbaro-Galtieri, VE Barnes, BA Barnett, P Barria, P Bartos, G Bauer, PH Beauchemin, F Bedeschi, D Beecher, S Behari, G Bellettini, J Bellinger, D Benjamin, A Beretvas, A Bhatti, M Binkley, D Bisello, I Bizjak, RE Blair, C Blocker, B Blumenfeld, A Bocci, A Bodek, V Boisvert, D Bortoletto, J Boudreau, A Boveia, B Brau, A Bridgeman, L Brigliadori, C Bromberg, E Brubaker, J Budagov, HS Budd, S Budd, K Burkett, G Busetto, P Bussey, A Buzatu, KL Byrum, S Cabrera, C Calancha, S Camarda, M Campanelli, M Campbell, F Canelli, A Canepa, B Carls, D Carlsmith, R Carosi, S Carrillo, S Carron, B Casal, M Casarsa, A Castro, P Catastini, D Cauz, V Cavaliere, M Cavalli-Sforza, A Cerri, L Cerrito, SH Chang, YC Chen, M Chertok, G Chiarelli, G Chlachidze, F Chlebana, K Cho, D Chokheli, JP Chou, K Chung, WH Chung, YS Chung, T Chwalek, CI Ciobanu, MA Ciocci, A Clark, D Clark, G Compostella, ME Convery, J Conway

Abstract:

The collection of a large number of B-hadron decays to hadronic final states at the CDF II Detector is possible due to the presence of a trigger that selects events based on track impact parameters. However, the nature of the selection requirements of the trigger introduces a large bias in the observed proper-decay-time distribution. A lifetime measurement must correct for this bias, and the conventional approach has been to use a Monte Carlo simulation. The leading sources of systematic uncertainty in the conventional approach are due to differences between the data and the Monte Carlo simulation. In this paper, we present an analytic method for bias correction without using simulation, thereby removing any uncertainty due to the differences between data and simulation. This method is presented in the form of a measurement of the lifetime of the B- using the mode B-→D0π -. The B- lifetime is measured as τB -=1.663±0.023±0.015ps, where the first uncertainty is statistical and the second systematic. This new method results in a smaller systematic uncertainty in comparison to methods that use simulation to correct for the trigger bias. © 2011 American Physical Society.

Pagination

  • First page First
  • Previous page Prev
  • …
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Current page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • …
  • Next page Next
  • Last page Last

Footer Menu

  • Contact us
  • Giving to the Dept of Physics
  • Work with us
  • Media

User account menu

  • Log in

Follow us

FIND US

Clarendon Laboratory,

Parks Road,

Oxford,

OX1 3PU

CONTACT US

Tel: +44(0)1865272200

Department Of Physics text logo

© University of Oxford - Department of Physics

Cookies | Privacy policy | Accessibility statement

  • Home
  • Research
  • 51ÁÔÆæÈë¿Ú
  • Engage
  • Our people
  • News & Comment
  • Events
  • Our facilities & services
  • 51ÁÔÆæÈë¿Ú
  • Giving to Physics