51ÁÔÆæÈë¿Ú

Skip to main content
Department Of Physics text logo
  • Research
    • Our research
    • Our research groups
    • Our research in action
    • Research funding support
    • Summer internships for undergraduates
  • 51ÁÔÆæÈë¿Ú
    • Undergraduates
    • Postgraduates
  • Engage
    • For alumni
    • For business
    • For schools
    • For the public
  • Support
Menu
Stacking faults in shock-compressed copper

Shock-induced stacking faults in dynamically compressed copper modelled using large-scale molecular dynamics simulations

Dr Patrick Heighway

Postdoctoral Research Assistant in High Energy Density Science

Research theme

  • Lasers and high energy density science

Sub department

  • Atomic and Laser Physics

Research groups

  • Oxford Centre for High Energy Density Science (OxCHEDS)
patrick.heighway@physics.ox.ac.uk
Clarendon Laboratory, room Simon
  • About
  • Publications

Featured Work

Molecular dynamics simulation of double-slip in a bcc crystal
Giving the slip to a metal deformation mystery

A kinematic model uses X-ray diffraction patterns to identify active slip systems during the dynamic compression of metals

Diffuse scattering from dynamically compressed single-crystal zirconium following the pressure-induced α → Ӭ phase transition

Physical Review B American Physical Society (APS) 110:5 (2024) 054113

Authors:

PG Heighway, S Singh, MG Gorman, D McGonegle, JH Eggert, RF Smith

Abstract:

The prototypical α → Ӭ phase transition in zirconium is an ideal test bed for our understanding of polymorphism under extreme loading conditions. After half a century of study, a consensus had emerged that the transition is realized via one of two distinct displacive mechanisms, depending on the nature of the compression path. However, recent dynamic-compression experiments equipped with diffraction diagnostics performed in the past few years have revealed new transition mechanisms, demonstrating that our understanding of the underlying atomistic dynamics and transition kinetics is in fact far from complete. We present classical molecular dynamics simulations of the α → Ӭ phase transition in single-crystal zirconium shock compressed along the [0001] axis using a machine-learning-class potential. The transition is predicted to proceed primarily via a modified version of the two-stage Usikov-Zilberstein mechanism, whereby the high-pressure Ӭ phase heterogeneously nucleates at boundaries between grains of an intermediate β phase. We further observe the fomentation of atomistic disorder at the junctions between β grains, leading to the formation of highly defective interstitial material between the Ӭ grains. We directly compare synthetic x-ray diffraction patterns generated from our simulations with those obtained using femtosecond diffraction in recent dynamic-compression experiments, and show that the simulations produce the same unique, anisotropic diffuse scattering signal unlike any previously seen from an elemental metal. Our simulations suggest that the diffuse signal arises from a combination of thermal diffuse scattering, nanoparticlelike scattering from residual kinetically stabilized α and β grains, and scattering from interstitial defective structures. Published by the American Physical Society 2024

Resonant inelastic x-ray scattering in warm-dense Fe compounds beyond the SASE FEL resolution limit

Communications Physics Nature Research 7:1 (2024) 266

Authors:

Alessandro Forte, Thomas Gawne, Karim K Alaa El-Din, Oliver S Humphries, Thomas R Preston, Céline Crépisson, Thomas Campbell, Pontus Svensson, Sam Azadi, Patrick Heighway, Yuanfeng Shi, David A Chin, Ethan Smith, Carsten Baehtz, Victorien Bouffetier, Hauke Höppner, Alexis Amouretti, David McGonegle, Marion Harmand, Gilbert W Collins, Justin S Wark, Danae N Polsin, Sam M Vinko

Abstract:

Resonant inelastic x-ray scattering (RIXS) is a widely used spectroscopic technique, providing access to the electronic structure and dynamics of atoms, molecules, and solids. However, RIXS requires a narrow bandwidth x-ray probe to achieve high spectral resolution. The challenges in delivering an energetic monochromated beam from an x-ray free electron laser (XFEL) thus limit its use in few-shot experiments, including for the study of high energy density systems. Here we demonstrate that by correlating the measurements of the self-amplified spontaneous emission (SASE) spectrum of an XFEL with the RIXS signal, using a dynamic kernel deconvolution with a neural surrogate, we can achieve electronic structure resolutions substantially higher than those normally afforded by the bandwidth of the incoming x-ray beam. We further show how this technique allows us to discriminate between the valence structures of Fe and Fe2O3, and provides access to temperature measurements as well as M-shell binding energies estimates in warm-dense Fe compounds.

Diffuse scattering from dynamically compressed single-crystal zirconium following the pressure-induced $\alpha\to\omega$ phase transition

(2024)

Authors:

PG Heighway, S Singh, MG Gorman, D McGonegle, JH Eggert, RF Smith

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: quantitative structural analysis of liquid Sn

Journal of Applied Physics AIP Publishing 135:16 (2024) 165902

Authors:

Mg Gorman, D McGonegle, Rf Smith, S Singh, T Jenkins, Rs McWilliams, B Albertazzi, Sj Ali, L Antonelli, Mr Armstrong, C Baehtz, Ob Ball, S Banerjee, Ab Belonoshko, A Benuzzi-Mounaix, Ca Bolme, V Bouffetier, R Briggs, K Buakor, T Butcher, S Di Dio Cafiso, V Cerantola, J Chantel, A Di Cicco, S Clarke, Al Coleman, J Collier, Gw Collins, Aj Comley, F Coppari, Te Cowan, G Cristoforetti, H Cynn, A Descamps, F Dorchies, Mj Duff, A Dwivedi, C Edwards, Jh Eggert, D Errandonea, G Fiquet, E Galtier, A Laso Garcia, H Ginestet, L Gizzi, A Gleason, S Goede, Jm Gonzalez, M Harmand, Nj Hartley

Abstract:

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ∼ 3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ∼ 1 % at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

Crystal plasticity finite element simulation of lattice rotation and x-ray diffraction during laser shock compression of tantalum

Physical Review Materials American Physical Society 7:11 (2023) 113608

Authors:

P Avraam, D McGonegle, Pg Heighway, Ce Wehrenberg, E Floyd, Aj Comley, Jm Foster, Sd Rothman, J Turner, S Case, Js Wark

Abstract:

We present a crystal plasticity model tailored for high-pressure, high-strain-rate conditions that uses a multiscale treatment of dislocation-based slip kinetics. We use this model to analyze the pronounced plasticity-induced lattice rotations observed in shock-compressed polycrystalline tantalum via in situ x-ray diffraction. By making direct comparisons between experimentally measured and simulated texture evolution, we can explain how the details of the underlying slip kinetics control the degree of lattice rotation that ensues. Specifically, we show that only the highly nonlinear kinetics caused by dislocation nucleation can explain the magnitude of the rotation observed under shock compression. We demonstrate a good fit between our crystal plasticity model and x-ray diffraction data and exploit the data to quantify the dislocation nucleation rates that are otherwise poorly constrained by experiment in the dynamic compression regime.

Pagination

  • First page First
  • Previous page Prev
  • Page 1
  • Page 2
  • Page 3
  • Current page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Next page Next
  • Last page Last

Footer Menu

  • Contact us
  • Giving to the Dept of Physics
  • Work with us
  • Media

User account menu

  • Log in

Follow us

FIND US

Clarendon Laboratory,

Parks Road,

Oxford,

OX1 3PU

CONTACT US

Tel: +44(0)1865272200

Department Of Physics text logo

© University of Oxford - Department of Physics

Cookies | Privacy policy | Accessibility statement

  • Home
  • Research
  • 51ÁÔÆæÈë¿Ú
  • Engage
  • Our people
  • News & Comment
  • Events
  • Our facilities & services
  • 51ÁÔÆæÈë¿Ú
  • Giving to Physics